<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AROUND LAB NEWS / IT &#187; Farmaceutica</title>
	<atom:link href="http://www.aroundlabnews.com/it/category/life-science/farmaceutica/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.aroundlabnews.com/it</link>
	<description></description>
	<lastBuildDate>Wed, 11 Mar 2020 09:08:31 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.5.1</generator>
		<item>
		<title>Clean room, RABS, Isolator</title>
		<link>http://www.aroundlabnews.com/it/clean-room-rabs-isolator/</link>
		<comments>http://www.aroundlabnews.com/it/clean-room-rabs-isolator/#comments</comments>
		<pubDate>Mon, 23 May 2016 08:06:36 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Clean Room]]></category>
		<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[Microbiologia]]></category>
		<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=10793</guid>
		<description><![CDATA[Clean Rooms, RABS and Isolators: Validation and Monitoring in the Diverse World of Aseptic Processing Link -&#62;&#62;&#62; Aseptic processing has become a diverse manufacturing technology, which is [...]]]></description>
				<content:encoded><![CDATA[<p><span style="font-size: 24px;"><strong>Clean Rooms, RABS and Isolators: Validation and Monitoring in the Diverse World of Aseptic Processing</strong></span></p>
<p><span style="font-size: 16px;"><a href="http://www.americanpharmaceuticalreview.com/Featured-Articles/36878-Clean-Rooms-RABS-and-Isolators-Validation-and-Monitoring-in-the-Diverse-World-of-Aseptic-Processing/" target="_blank">Link -&gt;&gt;&gt;</a></span></p>
<p><span style="font-size: 16px;">Aseptic processing has become a diverse manufacturing technology, which is to say that there are at least three major means of accomplishing an acceptable outcome. ‘Acceptable’ in this case is defined as, ‘an application of aseptic technology(s) that are approved for use by a competent regulatory authority.’ The major categories of aseptic processing technologies are:</span></p>
<p style="padding-left: 30px;"><span style="font-size: 16px;">1. Manned human-scale clean rooms (aseptic clean rooms)</span><br />
<span style="font-size: 16px;">2. Restricted Access Barrier Systems (RABS)</span><br />
<span style="font-size: 16px;">3. Isolation technology (Isolators)</span></p>
<p><span style="font-size: 16px;">If one considers that some firms have taken a mix and match approach the permutations are nearly endless. For example, the authors have observed single aseptic processing production lines in which isolators, RABS and clean rooms are used in combination. If we further consider that there are RABS systems which allow open door access (open-RABS) and those that do not (closed-RABS) the number of permutations increases [1]. Isolators can also be found in both ‘open’ and ‘closed’ designs [2].</span></p>
<p><span style="font-size: 16px;">Of course, these differences in aseptic technology would be completely inconsequential if all three of these major classes of technology, and permutations and variations resulted in truly equivalent performance. In a world of absolute technological equivalence a “one size fits all” approach to aseptic processing regulation would be both reasonable and rational philosophically, and even more importantly, scientifically legitimate.</span></p>
<p><strong><span style="font-size: 16px;">Different Means to the Same Outcome?</span></strong></p>
<p><span style="font-size: 16px;">One could, of course, say that obviously all of the technologies result in a uniform end, which is to say they are all accepted means to manufacture “sterile” products. Logically, since the definition of sterility most typically applied is complete absence of viable organisms for a condition of technological equivalence to be in place, the major categories of aseptic processing would be (should be) capable of equivalent outcomes. Now, the reader having come this far might be thinking that the authors are playing some kind of semantic game, because there is a general understanding that isolators, and certainly closed RABS are more capable (lower risk) contamination control modalities than aseptic clean rooms. In fact, the FDA’s principle aseptic processing guidance document asserts that isolators are superior in their ability to control contamination and suggests that this could accrue to benefits in reduced validation workload [3].</span></p>
<p><span style="font-size: 16px;">The authors strongly support the assertion that isolators are superior to manned clean rooms in their ability to restrict the entry of contamination into the manufacturing environment [4]. Though acknowledgement of this superiority can be found and suggestions of risk-based reduction in emphasis on standard validation and process control approaches can similarly be found in published regulatory opinion; industry remains a long way from a true risk- and science-based approach to aseptic processing [5].</span></p>
<p><strong><span style="font-size: 16px;">What Would a True Risk and Sciencebased Approach Look Like?</span></strong></p>
<p><span style="font-size: 16px;">The simplest and most direct way to implement a risk-based approach is to take proactive steps to minimize contamination released by humans in clean rooms. We find that both industry specialists and regulatory authorities tend to overemphasize contamination contributed by equipment, and processing environments relative to human borne contamination. We hear far too much discussion of contamination passing through HEPA filters (highly unlikely) and of contamination residing more or less permanently on walls and floors. Experience has taught us that most contamination in a clean room is transient and human sourced, so it follows that controlling human-derived contamination is the most effective way to reduce risk and, coincidentally, reduce environmental monitoring recovery (and reduce compliance risks in the bargain!).i</span></p>
<p><span style="font-size: 16px;">The most effective way to reduce human sourced contamination is simply to prevent it from entering the critical ISO 5 zone and the best way to do that is through the implementation of advanced aseptic processing technology. Advanced aseptic processing technology is quite simply defined as the elimination of interventions performed by gowned human operators [6]. Isolator technology works extremely well in this regard because it completely obviates a human-gowned presence in the critical zone.. Closed RABS systems approach this level of separation and automation accomplishes it by different but equally effective means. Increasingly we will see a combination of advanced separative technologies such as isolators and RABS used in conjunction with automation which will eliminate even those interventions currently made using glove/sleeve assemblies. Gloveless systems doing exactly that can be purchased today.</span></p>
<p><strong><span style="font-size: 16px;">Contemporary Human-scale Cleanrooms are Less Risk Intensive Than Prior Designs for the Following Reasons:</span></strong></p>
<p style="padding-left: 30px;"><span style="font-size: 16px;">1. The greatest single advancement in aseptic processing has been the elimination of interventions using various types of automation. Examples include, depyrogenation tunnels, automatic lyophilizer loading, clean-in-place/sterilize-in-place systems and automated weight check/adjustment.</span><br />
<span style="font-size: 16px;">2. A clear recognition of the importance of the need for sufficient air exchange.. Thirty years ago Class 100 was restricted to the zone immediately over the fill line and the total air changes per hour in the entire fill room rarely exceeded 100. Today, wall-to-wall HEPA coverage in ISO 5 environments is commonplace which results in up to 800 air changes per hour. Coupling this level of air movement with lower operator populations due to increased automation further reduces risk.</span><br />
<span style="font-size: 16px;">3. Improved gowning materials are effectively highly efficient filters and they are more effective at preventing human contamination from entering the workspace.</span></p>
<p><span style="font-size: 16px;">In even the best manned operations we often find that better attention to detail will reduce contamination risk further still. Two factors that can further reduce environmental monitoring “hits” are:</span></p>
<p style="padding-left: 30px;"><span style="font-size: 16px;">1. Being intolerant of equipment- and component-driven malfunctions. We often see poor component feeding, line jams and frequent line stoppages for adjustment. In aseptic processing poor performing equipment or improperly prepared (and thus poorly machineable ) components should not be tolerated at all [7].</span><br />
<span style="font-size: 16px;">2. Eliminating interventions to the maximum extent possible [8,9]. Our philosophy is that the only good intervention is the one that didn’t take place. This philosophy serves as the basis for our risk measurement and mitigation approach [10,11]. Just because clean room performance and operator gowns have improved doesn’t mean that interventions should be tolerated. The best aseptic operations are those in which inherent interventions are made as safe as possible and continued efforts are made for the elimination of corrective interventions.</span></p>
<p><strong><span style="font-size: 16px;">Controlling is Always Better than Measuring Contamination</span></strong></p>
<p><span style="font-size: 16px;">The advancements in aseptic processing over the last thirty years have made environmental monitoring substantially less useful than it once was [12]. We realize that this is a controversial statement and we understand that environmental monitoring is as heavily emphasized in regulatory inspections now as it was three decades ago, which means that a firm would ignore monitoring at some substantial peril. However, as a tool for identifying risk in aseptic processing it no longer provides the burning insights it did in the not too distant past when contamination control performance was substantially inferior. We honestly find reviewing aseptic processing environmental monitoring results in 2011 to be one of the most boring activities imaginable. In critical manned ISO 5 areas we typically see random low level counts. This means a long string of zeros interspersed with the very occasional recovery of a viable isolate. Take away the human operators through use of isolators or other advanced aseptic technologies and you have the long strings of zeros without any of the interspersed recoveries.</span></p>
<p><span style="font-size: 16px;">Ironically, the result of this improved performance manifesting itself as low recovery rates has resulted in a tendency to over-interpret the data. As “counts” become infrequent and low there began a tendency to try to parse differences between analytically and statistically identical findings. One obvious example is the establishment of alert and action levels that differ by one colony forming unit. Equally scientifically in appropriate are expectations that when low level microbial recoveries are seen major investigations are required and lot rejection should be considered. Microbiological sampling and recovery techniques used in monitoring simply don’t have sufficient sensitivity or discrimination for differences of this nature to have any scientific meaning. Nor do we have adequate controls to assure that the detected microbe was not the result of the sampling process and had no relation at all to the materials being produced. The fact is that modern manned clean rooms as good as they are aren’t “sterile” and unless we put people in hermetically sealed space suits we never will attain sterility within them. Therefore, wisdom requires the acceptance of the occasional evidence of a low level of random background counts.</span></p>
<p><span style="font-size: 16px;">Two statements we often hear made that betray a misunderstanding of monitoring metrology are:</span></p>
<p style="padding-left: 30px;"><span style="font-size: 16px;">1. Since we see so many zeroes we should increase monitoring intensity.</span><br />
<span style="font-size: 16px;">2. A single data point can be reflective of an adverse trend.</span></p>
<p><span style="font-size: 16px;">Really, increasing monitoring intensity in nearly all instances is only going to result in more zeroes, a phenomenon we’ve seen over and over again. Too often the most common intervention in aseptic processing is environmental monitoring, which is completely illogical. What this means is that the method erroneously relied upon to measure risk is itself the greatest source of human contamination risk! The fact is continuous monitoring for all the ballyhoo associated with it accomplishes little or nothing. In a clean room that provides hundreds of air changes per hour the volume of air moving through it is so large that sampling five or ten cubic meters per hour from a few continuous monitoring systems amounts to a sample so minuscule as to be trivial.</span></p>
<p><span style="font-size: 16px;">Trends in a modern clean room simply do not exist and defining a single data point as an adverse trend cannot change this fact. How can one consider a room in which the recovery of counts is something like 0.5% of the total samples taken and the majority of counts within a small number of normal human flora species to produce any kind of “trend.” The fact is it is rather pointless at this point in the development of aseptic technology to be thinking of trends, that word may have had meaning in the 1980’s when it entered the regulatory compliance lexicon, but aseptic processing today is a far different world.</span></p>
<p><strong><span style="font-size: 16px;">Monitoring, Validation and Modern Technology</span></strong></p>
<p><span style="font-size: 16px;">The more advanced our contamination control technologies become in aseptic processing the less useful monitoring itself becomes. In isolators and closed RABs monitoring efforts simply do not produce enough signal (data) to be useful. Observing lots and lots of zeroes is reassuring and provides some compliance comfort but it does not produce actionable data. Where advanced aseptic technologies are used we should be relying almost exclusively on evaluation of physical parameters, and electronic particulate monitoring, which produce data that can be reviewed in real time rather than requiring several days of incubation.</span></p>
<p><span style="font-size: 16px;">We believe that media fill testing in advanced aseptic technology should be reduced as well, in fact we consider it a wise regulatory strategy to make good on the promise of risk- and science-based regulation by eliminating as much validation busy work as possible. We believe this is consistent with the concept of quality by design. It should reasonably follow that when quality by design is taken seriously and done well, then antiquated methods no longer able to provide useful data regarding the performance of well-designed, high-quality systems should be either eliminated, or at least their usage greatly reduced.</span></p>
<p><strong><span style="font-size: 16px;">Manned Clean Rooms and Monitoring Requirements</span></strong></p>
<p><span style="font-size: 16px;">Aseptic processing can be more readily improved through the reduction of interventions and focus on improved operations than by monitoring. Monitoring in manned clean rooms will continue to have a purpose albeit an increasingly marginalized one. Here to, where operational history demonstrates that a continuous state-of-control at a baseline level has been established a reduction in monitoring and media fill testing is reasonable, proper and even prudent.</span></p>
<p><strong><span style="font-size: 16px;">Final Thoughts</span></strong></p>
<p><span style="font-size: 16px;">We realize that our thoughts regarding microbiological monitoring and traditional validation approaches as applied to modern aseptic processing will seem radical to some readers at first. Scientifically, however, we steadfastly believe our suggestions are eminently rational. It is only our culture that causes them to appear radical. Times change and hanging onto old ways beyond their usefulness is neither wise process control, nor wise regulation. Worse than hanging onto old ways is misapplying these old ways, because we are fearful of letting them go.</span></p>
<p><span style="font-size: 16px;">We leave you with one last warning, lately we have begun hearing that the problem with monitoring is that we haven’t yet sufficiently applied rapid instrumental microbiological technologies to the task. We’ve heard advanced the idea that all that stands between us and the ability to measure “sterility assurance” in process is better analytical technology. While some methods may bring with them the potential for increased sensitivity, they still fall prey to the realities of sampling statistics. Getting a test result hours or even minutes after it is taken has no bearing on whether the result has any real utility. Measuring sterility would require an assay capable of detecting any contaminant with total and absolute reliability and also the ability to take an infinite sample size. It is impudent to think that our culture of attempting to monitor quality into aseptic processes will somehow be perpetuated by new analytical technology.</span></p>
<p><span style="font-size: 16px;">Validation has long been recognized as advantageous because it breaks our reliance on testing quality into product. It seems obvious that it is equally impossible to monitor quality into a process or product. Newer initiatives such as quality by design and risk- and science-based processing (regulation) are like validation before them recognitions that testing quality into a system has real limitations. Monitoring quality into a system likewise has limitations, a fact we would be unwise to ignore.</span></p>
<p><span style="font-size: 16px;">Environmental monitoring is a tool and like any tool it must fit the task. As our ability to control contamination improves it is clear that this legacy “tool” has less much value than it once did when aseptic processing environments were in a less effective state of contamination control. As a tool to assert “sterility assurance” environmental monitoring is sorely lacking, as a tool to assess that an environment is essentially in a controlled state it is perhaps suitable. Accomplishing that realistic objective does not require an ever increasing increase in monitoring intensity.</span></p>
<p><span style="font-size: 16px;">We believe that in advanced aseptic systems electronic total particulate analysis either is largely sufficient to provide the information required to ensure the maintenance of a validated state of environmental control. If a microbiological sampling component is retained by regulators it should operate at a much lower sampling intensity than that currently expected in manned clean rooms. In highly automated manned clean rooms we believe that a reduced reliance on microbiological monitoring is reasonable and prudent. We see no reason why monitoring programs shouldn’t be sized to fit patient risk and consider the underlying process technology, as determined scientifically. We hope that experts from industry and the regulatory agencies can have frank discussions regarding the current state of aseptic process control and work cooperatively to devise the best scientific path forward. Aseptic processing as a discipline is advancing rapidly and we should not be tied to traditional practices however well entrenched they may be.</span></p>
<p><span style="font-size: 16px;">i A cleanroom is specifically designed to maintain a clean state through the selection of materials, HEPA filtered air supply, and other features that make it suitable for its intended purpose. When coupled with the rigorous decontamination regimes commonly used, they serve as poor environments for microbial survival let alone propagation.</span></p>
<p><strong><span style="font-size: 16px;">References</span></strong></p>
<p style="padding-left: 30px;"><em style="font-size: 16px;">1. ISPE RABS definition, circ 2005.</em><br />
<em style="font-size: 16px;">2. PDA, TR #34, “Design and Validation of Isolator Systems for the Manufacturing and Testing of Health Care Products”, PDA Journal of Pharmaceutical Science and Technology, Vol. 55 No. 5, supplement, 2001.</em><br />
<em style="font-size: 16px;">3. FDA, Guideline on Sterile Drug Products Produced by Aseptic Processing, 2004.</em><br />
<em style="font-size: 16px;">4. Agalloco, J., Akers, J., Madsen, R., “Choosing Technologies for Aseptic Filling &#8211; Back to the Future?”, Pharmaceutical Engineering, Vol. 27, No. 1, p 8-16, 2007.</em><br />
<em style="font-size: 16px;">5. FDA, Guideline on Sterile Drug Products Produced by Aseptic Processing, 2004.</em><br />
<em style="font-size: 16px;">6. Akers, J., Agalloco, J., Madsen, R., “What is Advanced Aseptic Processing?”, Pharmaceutical Manufacturing, Vol.4, No.2, pp 25-27, 2006.</em><br />
<em style="font-size: 16px;">7. Agalloco, J., Akers, J., “The Myth Called Sterility”, Pharmaceutical Technology, Vol. 34, No. 3, Supplement, pp. S44-45, 2010. Continued online at <a title="http://Pharmtech.com" href="http://pharmtech.com/" target="_blank">Pharmtech.com</a>.</em><br />
<em style="font-size: 16px;">8. Agalloco, J., Akers, J., “The Truth about Interventions in Aseptic Processing”, Pharmaceutical Technology, Vol. 31, No.5, p. S8-11, 2007.</em><br />
<em style="font-size: 16px;">9. Agalloco, J., &amp; Akers, J., “Revisiting Interventions in Aseptic Processing”, Pharmaceutical Technology, Vol. 35, No.4, pp 69-72, 2011.</em><br />
<em style="font-size: 16px;">10. Agalloco, J., Akers, J., “Risk Analysis for Aseptic Processing: The Akers-Agalloco Method”, Pharmaceutical Technology, Vol. 29, No.11, p. 74-88, 2005.</em><br />
<em style="font-size: 16px;">11. Agalloco, J., Akers, J., “Simplified Risk Analysis for Aseptic Processing: The Akers-Agalloco Method”, Pharmaceutical Technology, Vol. 30, No.7, p. 60-76, 2006.</em><br />
<em style="font-size: 16px;">12. Akers, J. &amp; Agalloco, J., “Environmental Monitoring &#8211; Myths and Misapplications”, PDA Journal of Pharmaceutical Science and Technology, Vol. 55, No. 3, p. 176-184, 2001.</em></p>
<p><strong><span style="font-size: 16px;">Author Biographies</span></strong></p>
<p><span style="font-size: 16px;"><em><strong>James E. Akers, Ph.D.</strong>, is President of Akers Kennedy &amp; Associates, Inc., located in Kansas City, MO. Dr. Akers has over 25 years experience in the Pharmaceutical industry and has worked at various director level positions within the industry and for the last decade as a consultant. Dr. Akers served as President of the PDA from 1991 to 1993 and as a member of the PDA Board of Directors from 1986-1999. Currently, he is Chairman of the USP Committee of Experts Microbiology and Sterility Assurance, as well co-chairman of the PDA Isolator Technology Task Force, Aseptic Processing Task force and member of several recent program committees.</em></span></p>
<p><span style="font-size: 16px;"><em>Dr. Akers has lectured world-wide, and taught numerous pharmaceutical technology courses world-wide including training for the US/FDA. Dr. Akers has also authored over eleven textbook chapters, edited a book on isolation technology, has a second book on isolator technology in preparation, and authored more than 100 technical and review articles on a variety of subjects including validation, aseptic processing, contamination control, environmental monitoring and control, biotechnology, isolator technology, sterilization and disinfection, sterility testing, media fill testing, HACCP analysis, pharmaceutical microbiology and regulatory compliance.</em></span></p>
<p><span style="font-size: 16px;"><em><strong>James Agalloco</strong> is President of Agalloco &amp; Associates, a technical service firm to the pharmaceutical and biotechnology industry. He was previously Director, Worldwide Validation and Automated Technology for Bristol-Myers Squibb. He received his BS in Chemical Engineering from Pratt Institute in 1968 and his MS, also in Chemical Engineering from Polytechnic Institute of New York in 1979. He received his MBA in Pharmaceutical Studies from Fairleigh Dickinson University in 1983. He is a past President of the Parenteral Drug Association and served as an Officer or Director from 1982 to 1993. He has served as a chairman and member of numerous PDA committees. He is a frequent author and lecturer on the subject of process and computer systems validations.</em></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/clean-room-rabs-isolator/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Vaccines 2015</title>
		<link>http://www.aroundlabnews.com/it/vaccines-2015/</link>
		<comments>http://www.aroundlabnews.com/it/vaccines-2015/#comments</comments>
		<pubDate>Fri, 25 Sep 2015 14:43:35 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[Micr. Farmaceutica]]></category>
		<category><![CDATA[Microbiologia]]></category>
		<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=10255</guid>
		<description><![CDATA[Courtyard by Marriott Berlin City Center While some view vaccines as a long established, traditional class of biologics, the arena of vaccinology provides some of the more [...]]]></description>
				<content:encoded><![CDATA[<div data-start="12/01/2015 07:00:00" data-end="12/02/2015 17:00:00">
<p><img class="alignnone size-full wp-image-10248" alt="call-for-papers-1" src="http://www.aroundlabnews.com/it/wp-content/uploads/2015/09/call-for-papers-1.jpg" width="627" height="234" /></p>
<p><strong><span style="font-size: 22px;">Courtyard by Marriott Berlin City Center</span></strong></p>
</div>
<div>
<p><span style="font-size: 16px;">While some view vaccines as a long established, traditional class of biologics, the arena of vaccinology provides some of the more exciting opportunities to bring forward new treatments, and to prevent a host of diseases that continue to cause public health concern. The 2015 PDA Vaccine Conference will provide a forum for discussion of many important topics in vaccine development and manufacturing, and related regulatory concerns as they relate to meeting the global demand for vaccines to prevent current and emerging infectious diseases.Vaccine stakeholders face the challenge of creating an environment that can accelerate the development, licensure, and availability of novel vaccine candidates for emerging epidemics and chronic infectious diseases. Advances in science and technology are giving rise to research and development for a wide array of new vaccines.  In addition, innovative manufacturing approaches are being applied in the production of these products. This is especially true for vaccines to address needs in developing countries and other international markets.</span></p>
<p><span style="font-size: 16px;">Over a span of two days, the 2015 PDA Vaccines Conference will examine the technical and regulatory challenges currently facing the vaccine industry and national regulatory authorities to facilitate the availability of these products to the global patient population. Participants will gain useful information about the current challenges facing the vaccines industry from renowned experts representing industry, regulatory and non-governmental organizations.</span></p>
<h3><span style="font-size: 16px;">Learning Objectives</span></h3>
<p><span style="font-size: 16px;">At the completion of this conference, participants will be able to:</span></p>
<ul>
<li><span style="font-size: 16px;">Identify emerging trends in vaccine manufacturing and development</span></li>
<li><span style="font-size: 16px;">Explain why vaccines represent a unique manufacturing challenge</span></li>
<li><span style="font-size: 16px;">Discuss the development and regulatory science of vaccines</span></li>
<li><span style="font-size: 16px;">Define in better detail the expectations for vaccine development using novel adjuvants</span></li>
</ul>
<h3><span style="font-size: 16px;">Who Should Attend</span></h3>
<p><span style="font-size: 16px;">Anyone involved in the manufacture and testing of vaccines for preventive and therapeutic purposes should attend this conference.</span></p>
<p><span style="font-size: 16px;">Specifically, pharmaceutical and biopharmaceutical professionals with the following responsibilities are encouraged to participate: Development | Manufacturing | Preclinical | Quality Assurance | Quality Control | Regulatory | Operations</span></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/vaccines-2015/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>The Universe of Pre-filled Syringes and Injection Devices 2015</title>
		<link>http://www.aroundlabnews.com/it/the-universe-of-pre-filled-syringes-and-injection-devices-2015/</link>
		<comments>http://www.aroundlabnews.com/it/the-universe-of-pre-filled-syringes-and-injection-devices-2015/#comments</comments>
		<pubDate>Wed, 23 Sep 2015 14:42:57 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[Micr. Farmaceutica]]></category>
		<category><![CDATA[Microbiologia]]></category>
		<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=10253</guid>
		<description><![CDATA[]]></description>
				<content:encoded><![CDATA[<p><a href="http://www.aroundlabnews.com/it/wp-content/uploads/2015/09/brochure1.pdf" target="_blank"><img class="alignnone size-full wp-image-10243" alt="brochure-1" src="http://www.aroundlabnews.com/it/wp-content/uploads/2015/09/brochure-11.jpg" width="627" height="887" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/the-universe-of-pre-filled-syringes-and-injection-devices-2015/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Pharmaceutical Cold &amp; Supply Chain Logistics 2015</title>
		<link>http://www.aroundlabnews.com/it/pharmaceutical-cold-supply-chain-logistics-2015/</link>
		<comments>http://www.aroundlabnews.com/it/pharmaceutical-cold-supply-chain-logistics-2015/#comments</comments>
		<pubDate>Tue, 22 Sep 2015 14:42:09 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[Micr. Farmaceutica]]></category>
		<category><![CDATA[Microbiologia]]></category>
		<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=10251</guid>
		<description><![CDATA[]]></description>
				<content:encoded><![CDATA[<p><a href="http://www.aroundlabnews.com/it/wp-content/uploads/2015/09/brochure.pdf" target="_blank"><img class="alignnone size-full wp-image-10235" alt="" src="http://www.aroundlabnews.com/it/wp-content/uploads/2015/09/brochure-1.jpg" width="627" height="887" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/pharmaceutical-cold-supply-chain-logistics-2015/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>CMC Regulatory Compliance for Biopharmaceuticals 2015</title>
		<link>http://www.aroundlabnews.com/it/cmc-regulatory-compliance-for-biopharmaceuticals-2015/</link>
		<comments>http://www.aroundlabnews.com/it/cmc-regulatory-compliance-for-biopharmaceuticals-2015/#comments</comments>
		<pubDate>Mon, 21 Sep 2015 14:39:22 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[Micr. Farmaceutica]]></category>
		<category><![CDATA[Microbiologia]]></category>
		<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=10249</guid>
		<description><![CDATA[]]></description>
				<content:encoded><![CDATA[<p><a href="http://www.aroundlabnews.com/it/wp-content/uploads/2015/09/brochure-1.pdf" target="_blank"><img class="alignnone size-full wp-image-10240" alt="brochure-(1)-1" src="http://www.aroundlabnews.com/it/wp-content/uploads/2015/09/brochure-1-1.jpg" width="627" height="887" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/cmc-regulatory-compliance-for-biopharmaceuticals-2015/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Risultati fuori specifica</title>
		<link>http://www.aroundlabnews.com/it/risultati-fuori-specifica/</link>
		<comments>http://www.aroundlabnews.com/it/risultati-fuori-specifica/#comments</comments>
		<pubDate>Sat, 11 Jul 2015 09:18:26 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Clean Room]]></category>
		<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[Microbiologia]]></category>
		<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=10038</guid>
		<description><![CDATA[Nel monitoraggio microbiologico ambientale di locali a contaminazione controllata, come ci si deve comportare in presenza di “risultati fuori specifica” come ad esempio superamento dei “limiti di [...]]]></description>
				<content:encoded><![CDATA[<p><span style="font-size: 16px;">Nel monitoraggio microbiologico ambientale di locali a contaminazione controllata, come ci si deve comportare in presenza di “risultati fuori specifica” come ad esempio superamento dei “limiti di allerta” o “limiti di azione”?</span></p>
<p><span style="font-size: 16px;">Le azioni da intraprendere possono essere:</span></p>
<p><span style="font-size: 16px;">-  Identificazione dei contaminanti</span></p>
<p><span style="font-size: 16px;">- Identificazione delle possibili cause</span></p>
<p><span style="font-size: 16px;">- Comunicazione delle relative informazioni necessarie al Responsabile di Produzione</span></p>
<p><span style="font-size: 16px;">- Verifica del “trend”della contaminazione microbica nelle ultime settimane / mesi</span></p>
<p><span style="font-size: 16px;">- Esecuzione di una serie di campionamenti microbiologici supplementari</span></p>
<p><span style="font-size: 16px;">- Controllo delle corretta pulizia e disinfezione e del sistema di condizionamento / ventilazione</span></p>
<p><span style="font-size: 16px;">- Accertamento delle corrette azioni correttive e preventive intrapprese</span></p>
<p><span style="font-size: 16px;">- Interventi sul prodotto finito (se necessario). </span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/risultati-fuori-specifica/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Corrective Action / Preventive Action</title>
		<link>http://www.aroundlabnews.com/it/corrective-action-preventive-action/</link>
		<comments>http://www.aroundlabnews.com/it/corrective-action-preventive-action/#comments</comments>
		<pubDate>Fri, 20 Mar 2015 13:54:58 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=9574</guid>
		<description><![CDATA[CA/PA helps with all issues. You identify and track corrective actions at your site. You can use issues that impact food safety and quality to help drive [...]]]></description>
				<content:encoded><![CDATA[<p><span style="font-size: 16px;">CA/PA helps with all issues. You identify and track corrective actions at your site. You can use issues that impact food safety and quality to help drive improvements to your programs and processes. </span></p>
<p><span style="font-size: 16px;"> When you have an event, you identify the issue, complete and record the &#8220;corrective&#8221; action. From there you want to look at what the root cause of the event was. Using the 5 whys is a great tool but there are several ways to drill back and find the root of the problem. Once you think you&#8217;ve found the root cause identity &#8220;preventive&#8221; actions to put in place to ensure the issue doesn&#8217;t reoccur. Once you&#8217;ve identified the actions needed add target completion dates and make sure to communicate the action items to the individuals assigned. 3-6 months after the action items have been completed go back and verify the effectiveness of the actions put in place. This closes out your CAPA. If the actions weren&#8217;t successful take another look at the root cause and the effectiveness of the assigned action items. </span></p>
<p><span style="font-size: 16px;"> Log the issues, use details like date the issue occurred, the department or site the event occurred, the specification, procedure, policy or regulatory requirement the nonconformity or event violated. You can use that to look at trends to identify improvements.</span></p>
<p><span style="font-size: 16px;"><a href="https://www.linkedin.com/groupItem?view=&amp;item=5947277669522567172&amp;type=member&amp;gid=3086951&amp;trk=eml-b2_anet_digest-hero-4-hero-disc-disc-0&amp;midToken=AQGvLKVVaGVtPQ&amp;fromEmail=fromEmail&amp;ut=0h81V63L71F6w1" target="_blank">Fonte &gt;&gt;&gt;</a></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/corrective-action-preventive-action/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>News and updates on pharmaceuticals</title>
		<link>http://www.aroundlabnews.com/it/news-and-updates-on-pharmaceuticals/</link>
		<comments>http://www.aroundlabnews.com/it/news-and-updates-on-pharmaceuticals/#comments</comments>
		<pubDate>Thu, 19 Mar 2015 13:48:56 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=9568</guid>
		<description><![CDATA[EudraLex &#8211; Volume 4 Good manufacturing practice (GMP) Guidelines. Volume 4 of &#8220;The rules governing medicinal products in the European Union&#8221; contains guidance for the interpretation of [...]]]></description>
				<content:encoded><![CDATA[<p><span style="font-size: 16px;"><b>EudraLex &#8211; Volume 4 Good manufacturing practice (GMP) Guidelines.</b></span></p>
<p><span style="font-size: 16px;">Volume 4 of &#8220;The rules governing medicinal products in the European Union&#8221; contains guidance for the interpretation of the principles and guidelines of good manufacturing practices for medicinal products for human and veterinary use laid down in Commission Directives 91/356/EEC, as amended by Directive 2003/94/EC, and 91/412/EEC respectively.</span></p>
<p><span style="font-size: 16px;"><a href="http://ec.europa.eu/health/documents/eudralex/vol-4/index_en.htm" target="_blank">Fonte &gt;&gt;&gt;</a></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/news-and-updates-on-pharmaceuticals/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Classificazione zone ad atmosfera controllata (BPF 2011-8 bis)</title>
		<link>http://www.aroundlabnews.com/it/classificazione-zone-ad-atmosfera-controllata-bpf-2011-8-bis/</link>
		<comments>http://www.aroundlabnews.com/it/classificazione-zone-ad-atmosfera-controllata-bpf-2011-8-bis/#comments</comments>
		<pubDate>Wed, 24 Sep 2014 13:30:14 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Biotecnologie]]></category>
		<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=8730</guid>
		<description><![CDATA[&#160; CLASSIFICAZIONE CONCENTRAZIONE PARTICELLARE MAX AMMISSIBILE (PARTICELLE / METRO CUBO &#160; CLASSIFICAZIONE  A RIPOSO A RIPOSO IN ATTIVITA’ IN ATTIVITA’   0,5 micron 5 micron 0,5 micron [...]]]></description>
				<content:encoded><![CDATA[<p>&nbsp;</p>
<table style="width: 620px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="100">
<p align="center"><span style="font-size: 16px;">CLASSIFICAZIONE</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">CONCENTRAZIONE PARTICELLARE MAX AMMISSIBILE (PARTICELLE / METRO CUBO</span></p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="width: 620px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="100">
<p align="center"><span style="font-size: 16px;"><span style="color: #ffffff;">CLASSIFICAZIONE</span> </span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">A RIPOSO</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">A RIPOSO</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">IN ATTIVITA’</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">IN ATTIVITA’</span></p>
</td>
</tr>
<tr>
<td valign="top" width="100">
<p align="center"><span style="font-size: 16px;"> </span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">0,5 micron</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">5 micron</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">0,5 micron</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">5 micron</span></p>
</td>
</tr>
<tr>
<td valign="top" width="100">
<p align="center"><span style="font-size: 16px;">Classe A</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">3520</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">20</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">3520</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">20</span></p>
</td>
</tr>
<tr>
<td valign="top" width="100">
<p align="center"><span style="font-size: 16px;">Classe B</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">3520</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">29</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">352.000</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">2.900</span></p>
</td>
</tr>
<tr>
<td valign="top" width="100">
<p align="center"><span style="font-size: 16px;">Classe C</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">352.000</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">2.900</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">352.000</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">29.000</span></p>
</td>
</tr>
<tr>
<td valign="top" width="100">
<p align="center"><span style="font-size: 16px;">Classe D</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">3.520.000</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">29.000</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">Non definito</span></p>
</td>
<td valign="top">
<p align="center"><span style="font-size: 16px;">Non definito</span></p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/classificazione-zone-ad-atmosfera-controllata-bpf-2011-8-bis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>PDA Europe: News and Events</title>
		<link>http://www.aroundlabnews.com/it/pda-europe-news-and-events/</link>
		<comments>http://www.aroundlabnews.com/it/pda-europe-news-and-events/#comments</comments>
		<pubDate>Mon, 24 Mar 2014 15:13:45 +0000</pubDate>
		<dc:creator>AROUND LAB NEWS / IT</dc:creator>
				<category><![CDATA[Estero]]></category>
		<category><![CDATA[Farmaceutica]]></category>
		<category><![CDATA[Life Science]]></category>
		<category><![CDATA[News]]></category>
		<category><![CDATA[Seminari]]></category>

		<guid isPermaLink="false">http://www.aroundlabnews.com/it/?p=8048</guid>
		<description><![CDATA[Regulatory News Feb. PDA Letter: Find out which PDA conference is volunteer Don Elinski’s in this issue’s Volunteer Spotlight. Plus, the India Chapter explores quality and sterility [...]]]></description>
				<content:encoded><![CDATA[<p><a href="http://www.pda.org/" target="_blank"><img class="alignnone size-full wp-image-8050" alt="Schermata-2014-03-24-alle-16.02.54" src="http://www.aroundlabnews.com/it/wp-content/uploads/2014/03/Schermata-2014-03-24-alle-16.02.54.jpg" width="610" height="158" /></a></p>
<p><span style="font-size: 16px;"><b>Regulatory News</b></span></p>
<p><span style="font-size: 16px;"><a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34178548&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=http://www.pda.org/pdaletter">Feb. PDA Letter: Find out which PDA conference is volunteer Don Elinski’s in this issue’s Volunteer Spotlight. Plus, the India Chapter explores quality and sterility assurance. And find out why your resume may not be generating interviews.</a></span></p>
<p><a href="https://europe.pda.org/index.php?n1=665&amp;n2=689&amp;id=1654&amp;content=Overview" target="_blank"><img class="alignnone size-full wp-image-8051" alt="Schermata-2014-03-24-alle-16.02.50" src="http://www.aroundlabnews.com/it/wp-content/uploads/2014/03/Schermata-2014-03-24-alle-16.02.50.jpg" width="366" height="196" /></a></p>
<p><span style="font-size: 16px;"><a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34178550&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/index.php?n1=665&amp;n2=713&amp;id=1574&amp;content=Overview"><b>VACCINES &amp; BEYOND</b></a> (Brussels, Belgium)</span></p>
<p><span style="font-size: 16px;"><b>April 29-30:</b> The aim of vaccine development is to design a stable product which is safe and efficacious for the intended patient population. Under a Quality by Design approach, product development begins with the establishment of predefined quality objectives. Such quality requirements are built on the basis of proven critical quality attributes (CQAs) &amp; related acceptance ranges. This session will be dedicated to selected case studies from different vaccine manufacturers, showing paths for the achievement of this challenging objective. The focus will be on: (i) identification of potential CQAs through product knowledge and risk- based approaches; (ii) understanding of the relationship between structural features and immunogenicity; (iii) practical implications on specifications settings &amp; process understanding, taking into account the need of periodic updates to incorporate the latest development data throughout the product’s lifecycle – <a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34178551&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/userfiles/downloads/2014_Vaccines_Agenda.pdf">Read More</a>.</span></p>
<p><span style="font-size: 16px;"><a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=32023145&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/index.php?n1=665&amp;n2=689&amp;id=1512&amp;content=Overview"><b>Advanced Therapy Medicinal Products</b></a><b> </b>(Madrid, Spain)</span></p>
<p><span style="font-size: 16px;"><b>une 3-4</b>: As ATMPs cover the most recent type of medicinal products of high complexity, there is a clear need to discuss the challenges in product development and in non-clinical and clinical testing. Meanwhile, first products are now moving through the regulatory approval path, and the field is starting to take shape, gradually maturing.</span><br />
<span style="font-size: 16px;"> <a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34625888&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/userfiles/downloads/2014_ATMPs_Brochure.pdf">This year’s program</a> will specifically focus on CMC development topics both in early and late development as well as illustrate new technical developments in the field. The Program Committee also intends to select a number of submitted posters for short oral presentation and discussion.</span><br />
<span style="font-size: 16px;"> Selected keynote lectures and a series of case studies encompassing a broad range of product types and development approaches will illustrate how ATMPs are currently being developed and tested. Examples will come from both the academic world and industry, and will cover cell therapy, gene therapy, and tissue engineering products. A careful selection of presentations aims to demonstrate ATMP diversity and the different aspects of their application and development. All this should set the stage for exchanging professional experience and new ideas in panel discussions. <a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34625889&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/userfiles/downloads/2014_ATMPs_Brochure.pdf">Read More.</a></span></p>
<p><span style="font-size: 16px;"><a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34178554&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/index.php?n1=665&amp;n2=689&amp;id=1511&amp;content=Overview"><b>Parenteral Manufacturing</b></a> (Istanbul, Turkey)</span></p>
<p><span style="font-size: 16px;"><b>June 24-25</b>: Our <a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34178555&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/userfiles/downloads/2014_ParManu_Agenda.pdf">conference</a> will provide an update on the most recent developments of Turkey and provides interfaces to international, EU and US regulations with case studies from leading global and domestic companies sharing their expert knowledge. Showing current and new technologies will enable you to manufacture state of the art products.</span><br />
<span style="font-size: 16px;"> The conference will be split into two main aspects: <b>Regulation and Technology.</b></span></p>
<p><span style="font-size: 16px;">- Our track on Regulation will discuss the local landscape framework compared to international harmonized systems such as PIC/S. It will cover the current discussions in Quality Systems, Inspection requirements and especially focus on future regulation trends in Turkey and worldwide.</span></p>
<p><span style="font-size: 16px;">- Our track on Technology will give an overview of current quality topics, equipment, infrastructure and devices. It will show the current state of the art technology. Case studies will highlight requests and solutions by describing just finalized projects in Turkey. <a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34178556&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/index.php?n1=665&amp;n2=689&amp;id=1511&amp;content=Overview">Read More.</a></span></p>
<p><span style="font-size: 16px;"><a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34178557&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/index.php?n1=665&amp;n2=710&amp;id=1671&amp;content=Overview"><b>GMP for APIs, a PIC/S-PDA Training Course</b></a> (Brussels, Belgium)</span></p>
<p><span style="font-size: 16px;"><b>September 18-19:</b> Regulatory inspectors from PIC/S and members of PDA developed this training course based on ICH Q7, taking into account the latest regulatory developments which impact APIs.</span><br />
<span style="font-size: 16px;"> This course will be held by inspectors and industry experts. It will start with an overview and provide background of API regulation. All 19 sections of Q7 will be covered. Inspectors will share observations from API manufacturing sites and there will be plenty of time to discuss in detail how to prepare for an inspection. Course participants will have the unique opportunity to receive answers to their specific questions.</span><br />
<span style="font-size: 16px;"> PDA believes there is no better way to get first-hand information about the current best-practice in API manufacturing and all related activities. Be sure to sign up soon, seats are filling quickly!</span><br />
<span style="font-size: 16px;"> Who should attend: API manufacturer, production, development, QA, QC functions, engineering – <a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=34625890&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=https://europe.pda.org/index.php?n1=665&amp;n2=710&amp;id=1671&amp;content=Overview">Read More.</a></span></p>
<p><a href="https://europe.pda.org/index.php?n1=665&amp;n2=689&amp;id=1513&amp;content=Overview" target="_blank"><img class="alignnone size-full wp-image-8053" alt="Schermata-2014-03-24-alle-16.03.07" src="http://www.aroundlabnews.com/it/wp-content/uploads/2014/03/Schermata-2014-03-24-alle-16.03.07.jpg" width="180" height="150" /></a>   <a href="https://europe.pda.org/index.php?n1=665&amp;n2=713&amp;id=1720&amp;content=Overview" target="_blank"><img class="alignnone size-full wp-image-8054" alt="Open" src="http://www.aroundlabnews.com/it/wp-content/uploads/2014/03/Open.jpg" width="180" height="150" /></a></p>
<p><span style="font-size: 16px;">PDA Europe gGmbH</span><br />
<span style="font-size: 16px;"> Adalbertstr. 9</span><br />
<span style="font-size: 16px;"> 16548 Glienicke/Berlin, Germany</span><br />
<span style="font-size: 16px;"> Tel.: +49 (0)33056 237710</span><br />
<span style="font-size: 16px;"> Fax: +49 (0)33056 237777</span><br />
<span style="font-size: 16px;"> <a href="http://www.mmsend7.com/link.cfm?r=1258011951&amp;sid=32023150&amp;m=3554891&amp;u=PDA_&amp;j=17637427&amp;s=http://europe.pda.org">https://europe.pda.org</a></span></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.aroundlabnews.com/it/pda-europe-news-and-events/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/

 Served from: www.aroundlabnews.com @ 2026-06-01 07:35:18 by W3 Total Cache -->